Hunter & McPherson
 
Disclaimer
Contact Us Home
       
 
Home > Generators > House Power Requirements


Generators for House Mains failure

House on Mains water   Total Watts Required Add 25% for nominal kVa rating
Watts kVa
Could survive with  
Lights - 8 at 75watts each 600 2,300 2,875 2.9
Fridge & Freezer 1,500
TV 200
Plus  
Heater / Air Conditioner OR Kettle 2,500 4,800 6,000 6.0
Heater / Air Conditioner AND Kettle 5,000 7,000 8,750 8.8

House with water pump   Total Watts Required Add 25% for nominal kVa rating
Watts kVa
Could survive with  
Lights - 8 at 75watts each 600 5,500 6,875 6.9
Fridge & Freezer 1,500
TV 200
Water Pump - to run 1,500
Water pump - start up current 1,700
Plus  
Heater / Air Conditioner OR Kettle 2,500   8,000   10,000   10.0
Heater / Air Conditioner AND Kettle 5,000   10,500   13,125   13.1

Add to above total if required  Watts   kVA 
Electric Oven 3,000 3.8
Electric Hot water service 3,000 3.8
Small heater 2,400 3.0
Kettle 2,400 3.0
Air Conditioner - room 2,400 3.0
Clothes dryer 2,400 3.0
Washing machine 2,000 2.5
Toaster 1,250 1.6
Iron 1,200 1.5
Vacuum Cleaner 1,200 1.5
Microwave oven 800 1.0

Above figures are indicitaive only. You must check your own equipment to ascertain your requirements.
A generator that is rated as 1kVa, can produce a maximum of 1,000 watts for a very short time (a few seconds).
It can only produce 80% of this figure for long periods of time, so a 1kVa generator is continuously rated at 800w watts.

 
       
 
459 Maroondah Hwy Lilydale, Vic, Australia 3140
 
 